Replacing the Auto Shutoff With a Solenoid Valve on Economy
Reverse Osmosis C/W Booster Pump (Model # EBP75TFC-3SF)
The kit (Part #92374) consists of the following
a) Solenoid Valve 24V (Qty 1)
b) Blue Wire Nuts (Qty 2)
c) Blue ¼” Tubing (9” length)
d) Red ¼” Tubing (14” length)
e) Black ¼” Tubing (19” Length)
f) Pull Ties (2)
g) Elbow ¼” NPT X ¼” Quick Connect
h) Adapter ¼” NPT X ¼” Quick Connect
i) Screw for the mounting the solenoid to the RO Bracket
Please verify that you have received all the components in the kit as described above
Tools Required:
• 11/16” Wrench
• Knife or Wire Stripper
• Phillips Screwdriver
Replacement Instructions
1. Disconnect the booster pump power supply.
2. Unscrew the white compression nut from the membrane housing using 11/16” wrench and disconnect the white tubing.
3. Remove the RO membrane housing from the clips and hang it to the side of the RO Module
#54920 1/11
RO Membrane
Housing
White
Compression
Nut
White Tubing
Disconnected
Przeglądanie stron 0
1 2 3 4 5 6 7

Podsumowanie treści

Strona 1 - Replacement Instructions

Replacing the Auto Shutoff With a Solenoid Valve on Economy Reverse Osmosis C/W Booster Pump (Model # EBP75TFC-3SF)The kit (Part #92374) consists of t

Strona 2

4. Remove the white tubing from the Auto Shut off as shown below. This tubing is the other end of the tubing removed from the RO membrane housing. Pu

Strona 3

7. Remove the white tubing connection to the outlet of the booster pump.8. Install the elbow (1/4” NPT X ¼” Quick Connect) supplied to the solenoid v

Strona 4

11. Connect one end of 9” blue tubing to the tee as shown below. Connect the other end of the blue tubing to the inlet of the solenoid valve.12. Con

Strona 5

14. Connect the 14” red tubing to the elbow of the middle sump. Connect the other end of the red tubing to the inlet of the booster pump.15. Take th

Strona 6

17. Locate the black and red wires coming from the pump. Follow these black and red wirers to the connector. On the other side of the connector cut t

Strona 7 - Flow Diagram

PUMPTRANSFORMERPOWERCORDSOLENOIDHIGH OR LOWPRESSURE SWITCHHIGH OR LOWPRESSURE SWITCHWIRENUTCLIPBLACK BLACKBLACKBLACKBLUEBLUEREDRED#54920 12/10WIRENUT

Komentarze do niniejszej Instrukcji